| Inverter
The Inverter is an important component of a PV system. Its primary function is to convert the direct current (DC) into alternating current (AC) to meet the demand or load for electricity.
Our sine wave inverters: S150, S300 & S600 provide excellent sine wave output for resistive, capacitive and inductive loads. The inverter’s power conversion processes utilizes high-frequency conversion technology. As a result, our inverters are lighter and more compact than similar products.
Its features are:
- Full isolation design for input and output
- Quick parallel start capacitor, inductive load
- 3-color LED to display input voltage, out voltage, load level and fault conditions
- Controlled fan cooling
- Advanced microprocessor control system
- Over voltage, under voltage, short-circuit, overload and over temperature protection
S150, S300 Specifications
| Specification |
Model No. |
| |
S150 |
S300 |
| Item |
S150-112 |
S150-124 |
S150-212 |
S150-224 |
S300-112 |
S300-124 |
S300-212 |
S300-224 |
| Continuous Output Power |
150W |
300W |
| Surge Rating |
200W |
400W |
| Input Voltage |
12V |
24V |
12V |
24V |
12V |
24V |
12V |
24V |
| Input Voltage Range |
10.5-15.0V |
21.0-30.0V |
10.5-15.0V |
21.0-30.0V |
10.5-15.0V |
21.0-30.0V |
10.5-15.0V |
21.0-30.0V |
| Output Voltage |
110V AC +/- 5% |
230V AC =+/- 5% |
110V AC +/- 5% |
230V AC =+/- 5% |
| Frequency (Switch Selections) |
50 / 60 Hz +/- 0.3% |
| Maximum Efficiency |
87% |
88% |
87% |
88% |
89% |
89% |
89% |
89% |
| No Load Current Draw |
<0.30A |
<0.35A |
| Output Waveform |
Pure Sine Wave (THD 6.0% Typical) |
| Power Factor Allowed |
cosθ -90° ~ cosθ +90° |
| Protection |
Overload, Short Circuit, Reverse Polarity (Fuse), Over/Under Input Voltage, Over Temperature |
| Remote Control |
Yes, On/Off, controlled by external switch |
| Safety Certification |
UL458, EN60950 |
| EMC |
| FCC Class B |
EN55022:1997 |
| FCC Class B |
EN61000-3-2: 1998 |
| FCC Class B |
EN61000-3-3:1995 |
| FCC Class B |
EN55024:2001 |
| Operating Temperature |
0 - 40°C |
| Storage Temperature |
-30°C – to 70°C |
| Fan Cooling |
Thermostat controlled |
| Dimensions (L x W x H) |
200mm x 132mm x 72mm/7.87in x 5.20in x 2.83in |
| Weight |
2.7 kgs/5.4 lbs. |
S600 Specifications
| Specification |
Model No. |
| |
S600 |
| Item |
S600-112 |
S600-124 |
S600-148 |
S600-212 |
S600-224 |
S600-248 |
| Continuous Output Power |
600W |
| Maximum Output Power(3Min.) |
680W |
| Surge Rating |
800W |
| Input Voltage |
12V |
24V |
48V |
12V |
24V |
48V |
| Input Voltage Range |
100V/110V/120V +/-3% |
220V/230V/240V +/-3% |
| Output Voltage |
110V AC +/- 5% |
230V AC =+/- 5% |
110V AC +/- 5% |
| Frequency (Switch Selections) |
50 / 60 Hz +/- 0.05% |
| Maximum Efficiency |
87% |
90% |
92% |
90% |
93% |
94% |
| No Load Current Draw |
0.87A |
0.43A |
0.23A |
0.83A |
0.43A |
0.22A |
| Output Waveform |
Pure Sine Wave (THD < 3%) |
| Input Voltage Regulation |
10.5 - 15V DC |
21.0 - 30V DC |
42 - 60V DC |
10.5 - 15V DC |
21.0 - 30V DC |
42 - 60V DC |
| Input Level Regulation |
Red/Orange/Green LED |
| Load Level Indicator |
| |
Overload, Short Circuit, Reverse Polarity (Fuse), Over/Under Input Voltage, Over Temperature |
| Safety Certification |
UL458, EN60950 |
UL458, EN60950 |
| EMC |
FCC Class B |
EN50081-1:1992; EN50082-1:1992; EN55022B:1994; EN61000-4-2:1995; EN61000-4-3:1996; ENV50204:1995 |
e-mark e13-020866 |
| Operating Temperature Range |
0 - 40°C |
| Storage Temperature Range |
30°C to 70°C |
| Fan Cooling |
Loading controlled cooling fan |
| Dimensions (L x W x H) |
295mm x 180mm x 72mm/11.61in x 7.09in x 2.83in |
| Weight |
2.7 kgs/5.4 lbs. |