Altius Consulting
 
Global Green Impact
Home | Events | Downloads | Contact us

Inverter

The Inverter is an important component of a PV system.  Its primary function is to convert the direct current (DC) into alternating current (AC) to meet the demand or load for electricity.

Our sine wave inverters: S150, S300 & S600 provide excellent sine wave output for resistive, capacitive and inductive loads.  The inverter’s power conversion processes utilizes high-frequency conversion technology.  As a result, our inverters are lighter and more compact than similar products.

Its features are:

  • Full isolation design for input and output
  • Quick parallel start capacitor, inductive load
  • 3-color LED to display input voltage, out voltage, load level and fault conditions
  • Controlled fan cooling
  • Advanced microprocessor control system
  • Over voltage, under voltage, short-circuit, overload and over temperature protection

S150, S300 Specifications

Specification Model No.
S150 S300
Item S150-112 S150-124 S150-212 S150-224 S300-112 S300-124 S300-212 S300-224
Continuous Output Power 150W 300W
Surge Rating 200W 400W
Input Voltage 12V 24V 12V 24V 12V 24V 12V 24V
Input Voltage Range 10.5-15.0V 21.0-30.0V 10.5-15.0V 21.0-30.0V 10.5-15.0V 21.0-30.0V 10.5-15.0V 21.0-30.0V
Output Voltage 110V AC +/- 5% 230V AC =+/- 5% 110V AC +/- 5% 230V AC =+/- 5%
Frequency (Switch Selections) 50 / 60 Hz +/- 0.3%
Maximum Efficiency 87% 88% 87% 88% 89% 89% 89% 89%
No Load Current Draw <0.30A <0.35A
Output Waveform Pure Sine Wave (THD 6.0% Typical)
Power Factor Allowed cosθ -90° ~ cosθ +90°
Protection Overload, Short Circuit, Reverse Polarity (Fuse), Over/Under Input Voltage, Over Temperature
Remote Control Yes, On/Off, controlled by external switch
Safety Certification UL458, EN60950
EMC
FCC Class B EN55022:1997
FCC Class B EN61000-3-2: 1998
FCC Class B EN61000-3-3:1995
FCC Class B EN55024:2001
Operating Temperature 0 - 40°C
Storage Temperature -30°C – to 70°C
Fan Cooling Thermostat controlled
Dimensions (L x W x H) 200mm x 132mm x 72mm/7.87in x 5.20in x 2.83in
Weight 2.7 kgs/5.4 lbs.

S600 Specifications

Specification Model No.
S600
Item S600-112 S600-124 S600-148 S600-212 S600-224 S600-248
Continuous Output Power 600W
Maximum Output Power(3Min.) 680W
Surge Rating 800W
Input Voltage 12V 24V 48V 12V 24V 48V
Input Voltage Range 100V/110V/120V +/-3% 220V/230V/240V +/-3%
Output Voltage 110V AC +/- 5% 230V AC =+/- 5% 110V AC +/- 5%
Frequency (Switch Selections) 50 / 60 Hz +/- 0.05%
Maximum Efficiency 87% 90% 92% 90% 93% 94%
No Load Current Draw 0.87A 0.43A 0.23A 0.83A 0.43A 0.22A
Output Waveform Pure Sine Wave (THD < 3%)
Input Voltage Regulation 10.5 - 15V DC 21.0 - 30V DC 42 - 60V DC 10.5 - 15V DC 21.0 - 30V DC 42 - 60V DC
Input Level Regulation Red/Orange/Green LED
Load Level Indicator
Overload, Short Circuit, Reverse Polarity (Fuse), Over/Under Input Voltage, Over Temperature
Safety Certification UL458, EN60950 UL458, EN60950
EMC FCC Class B EN50081-1:1992; EN50082-1:1992; EN55022B:1994; EN61000-4-2:1995; EN61000-4-3:1996; ENV50204:1995 e-mark e13-020866
Operating Temperature Range 0 - 40°C
Storage Temperature Range 30°C to 70°C
Fan Cooling Loading controlled cooling fan
Dimensions (L x W x H) 295mm x 180mm x 72mm/11.61in x 7.09in x 2.83in
Weight 2.7 kgs/5.4 lbs.

Download This Brochure

Altius Consulting. Global Green Impact
Altius Consulting is an affiliate of Executive Learning Center, China. 2010 All rights reserved.
(86 10) 8171 0487; (86) 1501 0905 484; (63) 920 928 0921; ramil@altiussystems.biz
www.altiussystems.biz
Help protect the environment. Print only when absolutely necessary.